The Romet RM meter is our tried-and-true classic design.
This all-aluminum cast meter has stood the test of time, providing users with reliable and accurate measurement for custody transfer. The RM meter provides multiple configuration options: Flange (ANSI and DIN), Nipple (NPT), and Hub (30Lt to 100Lt).

Rugged

All meters are pressure tested up to 4x MAOP to ensure only the toughest meters leave our facility. All RM meters have a 175 MAOP

Responsive

Each meter is individually factory tested and certified for measurement accuracy meeting or exceeding ANSI B109.3 rotary gas meter requirements.

Reliable

Pinned metal timing gears ensure the impellers are continuously synchronized to maintain the highest level of accuracy throughout the meter's lifespan.

Flange Configuration

The flange configuration provides a flat face (FF) flange metering solution for a variety of pipe dimensions.

  • ANSI or DIN flange options available
  • Flange configuration is available for the entire size range of RM rotary meters:
  • RM600 to RM56000 (imperial)
  • RM16 to RM1600 (soft metric)
  • G10 to G1000 (hard metric)
  • Available flange dimensions
  • 2", 3", 4", 6", 8"
  • DN40, DN80, DN100, DN150, DN200
Nipple Configuration

Nipple Configuration

The nipple configuration provides a 1.5" NPT connection. This configuration is available for specific meter sizes.

  • 1.5" NPT connection available for specific meter sizes:
  • RM600, RM1000, RM1500 (imperial)
  • RM16, RM30, RM40 (soft metric)
  • G10, G16, G25 (hard metric)
Hub Configuration

Hub Configuration

The Hub Configuration is designed to fit any application where an eleven inch (11") centre-to-centre hub connection meter would be utilized (800/1000 class diaphragm, ultrasonic, enclosed rotary cartridge).

  • 11" centre-to-centre hub connection is available for specific meter sizes:
  • RM600, RM1000, RM1500 (imperial)
  • RM16, RM30, RM40 (Soft Metric)
  • The Hub Configuration provides integrated AdEM® Electronics
  • Serial communications
  • 4 available pulse outputs
  • Full audit trail data log
  • BrightLync® compatibility
  • Built-in debris sump
  • Inlet and outlet pressure plugs
Principles of Operation

Romet measurement devices utilize positive displacement rotary technology. Rotary technology relies on the rotation of two figure eight shaped impellers to perform the measurement operation. These impellers have shafts held in low friction bearings and positioned 90 degrees in relation to each other by precision timing gears. The impellers contra rotate in semi cylindrical housings enclosed by head plates at either end. Very close tolerances and timing gears insure that an effective capillary seal is achieved, at the same time insuring that the impellers and housing do not come in contact. As gas enters the inlet of the meter, a pressure differential is created from the inlet and outlet of the meter, causing the impellers to rotate. The volume displaced by each revolution of the impellers is transmitted to a final module readout to begin collecting and organizing the generated data.

Technical Specifications (Imperial)

DOWNLOAD   RM600 Imperial Meter with 2" Flanged Connections
DOWNLOAD   RM600 Imperial Meter with 1.5" NPT Connections
DOWNLOAD   RM1000 Imperial Meter with 2" Flanged Connections
DOWNLOAD   RM1000 Imperial Meter with 1.5" NPT Connections
DOWNLOAD   RM1500 Imperial Meter with 2" Flanged Connections
DOWNLOAD   RM1500 Imperial Meter with 1.5" NPT Connections
DOWNLOAD   RM2000 Imperial Meter with 2" Flanged Connections
DOWNLOAD   RM3000 Imperial Meter with 2" Flanged Connections
DOWNLOAD   RM5000 Imperial Meter with 3" Flanged Connections

 

DOWNLOAD   RM7000 Imperial Meter with 3" Flanged Connections
DOWNLOAD   RM11000 Imperial Meter with 4" Flanged Connections
DOWNLOAD   RM16000 Imperial Meter with 4" Flanged Connections
DOWNLOAD   RM23000 Imperial Meter with 4" Flanged Connections
DOWNLOAD   RM25000 Imperial Meter with 6" Flanged Connections
DOWNLOAD   RM38000 Imperial Meter with 6" Flanged Connections
DOWNLOAD   RM38000 Imperial Meter with 8" Flanged Connections
DOWNLOAD   RM56000 Imperial Meter with 6" Flanged Connections
DOWNLOAD   RM56000 Imperial Meter with 8" Flanged Connections
Installation Instructions
DOWNLOAD   RM Installation Instructions

Education

Interested in attending a training class?

Visit Course Listing